This listing is for a lightly used TandD MCR-4V 4 Channel Voltage Data Logger with Graphing Display.
The MCR-4V works perfectly and was rarely used.
Located in Xenia, Ohio 45385
This includes the following:
TandD MCR-4V 4 Channel Voltage Data Logger
SD Card Adapter
16GB Micro SD Card
(2) AA Alkaline Batteries
USB Cable
User's Manual
Note: All software is downloaded from the TandD website.
TandD MCR-4V 4-Channel Voltage Data Logger w/ Graphing LCD Display
Measure and Record Voltage Readings in 4 Different Measurement Ranges Up to 24 Volts DC
Data Transfered to PC for Analysis Using USB (Cable Included) or SD Card
Touch Panel for Setup and Configuration Changes in the Field
4 Units Can be Coupled Together for up to 16 Channel Recording Simultaneously
LCD Display Shows Current Readings, Trend Graph, Battery Status and Configuration Settings
TandD MCR-4V 4-Channel Voltage Data Logger Specifications
Measurement Voltage (Up to 4 Channels)
Voltage Measurement Range: ±300mV; ±1.5V; ±6.0V; ±24V and Auto*
Absolute Max. Measurement Range: ±50 Volts
Breakdown Voltage: ±28 Volts
Accuracy: ±0.3%
Input Frequency: 100 Hz DC
Input Impedance: Approx. 1.1 MΩ
Input Method: Scaning Method, Diff. Input, Each Channel Isolated
Resolution: 0.01 mV (50/60 Hz Filter On); 0.1 mV (50/60Hz Filter Off)
* Measurement Range will be Automatically Changed According to the Voltage Being Measured
Preheat Function Voltage Range: 3V to 24 Volts (External Power Supply)
Allowable Max Current: 1.0 Amps
Recording Method Instanteous, Average (Ave), Fine
Sampling Interval 2, 5, 10, 20, 50, 100, 200, 500 ms
1, 2, 5, 10, 15, 20, 30 Seconds
1, 2, 5, 10, 15, 20, 30, 60 Minutes
Minimum Interval will Depend on the Number of Channels, Measurement Range and Hz Filter Setting
Data Storage Capacity Up to 480,000 Readings (1 Channel); Up to 240,000 Readings (2 Channels); Up to 160,000 (3 Channels); Up to 120,000 Readings (4 Channels)
Recording Mode Endless: Overwrite Oldest Data when Capacity is Full
One-time: Stop Recording when Capacity is Full
Group Recording Up to 4 Units (16 Channels) Can Be Recorded Simultaneously
Start Modes Immediate or Programmed
LCD Display Current Readings, Battery Life and Trend Graph
Power (2) AA (Alkaline or Lithium) Battery
USB Powered
Battery Life 4.5 Days to 150 Days
NOTE: Battery Life Depends on Measurement Environment, Sampling Interval and Battery Performance
Communication Type USB
External Storage SD Memory Card (SDHC Memory Card) - Sold Separately
NOTE: Measurement Data Cannot be Directly Recorded onto the Memory Card. Used to Transfer Recorded Data from Data Logger to PC Only.
Input and Preheat Terminals Screwless Terminals
Single Wire: 0.32mm to 0.65mm (28 AWG to 22 AWG)
Twisted Wire: 0.08 to 0.32mm (28 to 22 AWG). 0.12mm or More in Diameter
Strip Length: 9mm to 10mm
Isolation CH1, CH2, CH3, CH4, USB and Preheat are Isolated
Max Applied Voltage: 50 Volts
Electrical Isolation Resistance: 50 MΩ or More
NOTE: Battery Terminals are Not Isolated from CH1 to Ch4 Input Terminals
Operating Environment Temperature: 0°C to 50°C
Humidity: 90%RH or Less (No Condensation)
Weight 190 grams (Includes Battery)
Dimension 120mm x 75mm x 32mm